Beretta Novella E Models
Models are also cast iron, for one circuit, additional connection of water heaters is possible. There are eight different modifications, consider them.
Table number 7. Characteristics of equipment from the Novella E line
Model name | Power, in kilowatts | type of instalation | Number of circuits | Type of combustion chamber | Cost, in rubles |
Novella 27 E R.A.I. PV | 27 | floor | 1 | open | 99 674 |
Novella 35 E R.A.I. | 35 | floor | 1 | open | 93 755 |
Novella 35 E R.A.I. PV | 35 | floor | 1 | open | 106 866 |
Novella 43 E R.A.I. | 43 | floor | 1 | open | 101 647 |
Novella 51 E R.A.I. | 51 | floor | 1 | open | 110 112 |
Novella 61E R.A.I. | 61 | floor | 1 | open | 127 870 |
Novella 70E R.A.I. | 70 | floor | 1 | open | 139 009 |
Novella 78 E R.A.I. | 78 | floor | 1 | open | 150 787 |
Installation instructions
If the above requirements are not met, the gas service will not allow the boiler to be connected to the central line. However, the need to comply with these requirements is not dictated by bureaucracy, but by experience, as well as fire safety. Restrictions apply not only to equipment and installation work, but also to the premises where the boiler is supposed to be installed.
It must be remembered that the area of \u200b\u200bthe boiler room should be equal to 4 square meters or more, and the ceilings should not be lower than 2.5 meters. When installing the door, it should be taken into account that its width should be 80 cm or more
If you decide to prefer the Beretta manufacturer, the gas boiler of this company will meet all safety requirements, but it is important to follow the established rules. They suggest the need to illuminate equipment in a natural way through a window opening.
For 10 square meters of one room there should be 0.3 square meters of window opening. It is very important to organize intensive ventilation, because gas combustion is ensured by the principle of fresh air inflow. To ensure the intake of outside air, it is necessary to ensure the presence of an opening of 8 centimeters square per 1 kilowatt of device power.
Beretta CIAO 24 CAI
This unit is designed for wall mounting, it has two circuits for heating - heating and hot water circuits, while the combustion chamber is of an open type. What are the main advantages of this equipment? Listed below.
- There is an information display.
- Power can be adjusted smoothly.
- Automatic adjustment of the temperature regime of the coolant.
- The circulation pump has three speeds and is fail safe.
- Ability to reconfigure equipment for liquefied gas.
- The wall thickness of the heat exchanger has been increased on the latest models.
- The unit has an ionization type flame control.
- The water pressure is controlled by a hydraulic pressure switch.
- There is also smoke control.
In order to understand how this unit works, we give a brief instruction on this double-circuit gas boiler Beretta wall-mounted type.
- Operating modes are displayed by special icons on the indicator panel of the unit.
- To activate the operation of the equipment, it is necessary to turn on the power supply, open the gas cock, set the room temperature controller and set the "winter" or "summer" mode according to the situation.
- Shutdown is made by the special button "shutdown".
The described device has some relative disadvantages. We list them below:
- since the combustion chamber is open, it is necessary to have an equipped chimney in the room;
- sensors may be clogged.
We have dealt with this model, and now we will study another model.
Wall-mounted Beretta CITY 24 CSI
This equipment also provides for wall mounting. There are also two circuits here, but the combustion chamber is closed, respectively, the removal of smoke is forced. Power is 24 kW, and the area of the heated room can reach 240 m2.
The main best qualities of the equipment are listed below.
- copper primary heat exchanger;
- protection against freezing and overheating;
- automatic diagnostics of equipment errors;
- heating medium heating temperature is regulated automatically;
- power is regulated smoothly;
- frost protection and pump blocking.
As you can see, the functions of this model are similar to those of the previous model. Now we give a brief instruction manual for the described Beretta gas boiler.
- Icons are also used on the display panel, conditional images are deciphered in the technical data sheet.
- It is possible to connect a remote control.
- Installation rules are described in detail on the pages of the technical passport.
- The passport shows a connection diagram for a horizontal coaxial chimney, which must be purchased separately.
- To start the equipment, it is necessary to fill the system with water, turn on the power, open the gas cock, set the regulator to room temperature. Turn on the "winter" or "summer" mode.
- The equipment is turned off by the off button.
The detailed manual also lists error codes. That is, these are encrypted malfunctions that the Beretta double-circuit gas boiler can show on the display panel. However, we will now talk about them in more detail.
Comparison and problems
To summarize, we made a summary table for the two described models. The result is this: the boilers are approximately similar, and both are very attractive to the consumer. Here is that table:
The table below includes information about the malfunctions of a Beretta gas boiler that have occurred with consumers.
Let's write down what you can try to do with one or another malfunction with your own hands.
- Among the malfunctions of the Beretta gas boiler, there may be breakdowns in which the unit does not turn on. Most likely, the reason is either the lack of water or the lack of power. The worst case scenario is a motherboard failure. Only the service department will help here.
- It is possible to block due to overpressure of the chimney, but this may occur due to strong street wind.
- Malfunctions of sensors automatics should define itself.
- The equipment may also not turn on due to condensate in the chimney, the latter must be checked, among other things, if the unit does not turn on.
- There are cases of equipment failure due to frost at the chimney outlet. The sensor is triggered, as a result, the equipment does not work.
Here are the main problems that you may encounter during the operation of the described boiler equipment.