How to turn on and turn off the heating boiler
Putting the boiler into operation with the EuroSit 630 automation
- make sure that the gas cock on the gas pipeline in front of the boiler is closed,
- make sure that the boiler is turned off - the thermostat knob is in the ignition position,
- open the tap on the gas pipeline,
- turn the thermostat knob counterclockwise to align the asterisk icons on the panel knobs,
- smoothly press the knob of the thermostat in the axial direction until it stops and hold it,
- press the piezo lighter button several times (the burner should light up),
- keep holding the thermostat knob down for at least 10 seconds. (until the ignition burner goes out when it is released),
- release the thermostat knob (the ignition burner must be on),
- turn the thermostat knob anti-clockwise towards position "7", the main burner should light up.
Attention: if the ignition burner is extinguished, the ignition operation should be repeated again, but not earlier than after 3 minutes. Switching off the boiler with automatic equipment "EuroSit 630"
Switching off the boiler with automatic equipment "EuroSit 630"
- it is necessary to smoothly turn the temperature setting knob clockwise until the white asterisk is aligned with the asterisk sign on the panel,
- it is necessary to close the valve on the gas pipeline supply.
Putting the boiler into operation with the MiniSit 710 automation
- make sure that the gas cock on the gas pipeline in front of the boiler is closed,
- make sure that the boiler is turned off - the thermostat knob is in the ignition position,
- open the tap on the gas pipeline,
- press the ignition button and keep it pressed,
- press the piezo lighter button several times (the burner should light up),
- keep holding the ignition button pressed for at least 10 seconds. (until the ignition burner goes out when it is released),
- release the ignition button (the ignition burner must be on),
- turn the temperature setting knob counterclockwise towards position "7", the main burner should ignite.
Attention: if the ignition burner is extinguished, the ignition operation should be repeated again, but not earlier than after 3 minutes. Turning off the boiler with automatic "MiniSit 710"
Turning off the boiler with automatic "MiniSit 710"
- it is necessary to smoothly turn the temperature setting knob clockwise of the stop and press the off button,
- it is necessary to close the valve on the gas pipeline supply.
Putting the boiler into operation with automatics "Kare"
- make sure that the gas cock on the gas pipeline in front of the boiler is closed,
- turn the temperature sensor adjustment knob counterclockwise until it stops,
- open the tap on the gas pipeline,
- press and hold the solenoid valve trigger,
- press and release the button of the piezo lighter (you may have to press it several times until the ignition burner starts to burn),
- when the ignition burner starts to burn, continue to hold the solenoid valve start button for at least 30 seconds. (until the ignition burner goes out when it is released),
- by turning the nut on the ignition burner, it is necessary to achieve a blue flame on the burner,
- turn (smoothly, effortlessly) the thermostat knob to the right until the main burner ignites,
- set the desired temperature.
Attention: if the ignition burner goes out, the ignition operation should be repeated again, but not earlier than after 30 seconds
Expert answers
Konstantin Sukhorukov:
Look at here
Josef Schweik:
Have you tried reading the manual? Everything is intelligibly painted there and there is even a connection diagram (drawing) ... If there is no instruction, look it up on the Internet (I found it before answering you (in 2 minutes).
Online magazine Tips for hosts:
Imagine that you don’t have a second circuit, but just a water heater or boiler. Cold water enters through one pipe, hot water comes out through the second. That's the whole trick.
Taps, or rather mixers, of course, you need water-folding ones, from where you will collect hot water. Well, and an emergency valve, so that it would be possible to completely shut off the system in the event of an accident (say, a pipe burst). It is possible to additionally power the heating circuit from hot water, if automatic pumping of water into the heating system is not provided, and the expansion tank is open, then you will need a valve on this connection.
Well, in the rest, if the crane is needed exactly somewhere and for something. Some kind of outlet is there, but you never know what else you want to connect to hot water ... )
Alexei:
read the instructions, if it is possible to connect an external boiler for preparing hot water, say 200 liters, then you will have a hot bath and shower.
If there is only a built-in boiler and flow directly from it, then you will have only 1-2 liters of hot water per minute, enough for a washstand
sergey to:
the thermocouple heats up. better to block the valve altogether, so as not to go out
Ravza95:
Yes, along the way, it's because of the "B". There was such a case, only the boiler is different. Until the water in the entire system warmed up to operating temperature, the boiler turned off. As a result, this sensor “B” was short-circuited and thrown out, the boiler is still working, for 5 years already.
Anatoly Bondar:
B is a thermocouple that generates voltage when heated. The solenoid valve is powered by this voltage. Possible problems: 1. Reduce the draft in the chimney (gate, damper), so that the igniter flame does not break off. In rare cases - Slightly (without fanaticism) tighten the nut. which clamps the contact of this thermocouple at the input to the control unit.